Standard Platinum Resistance Thermometer

Standard Platinum Resistance Thermometer

◇ Product Introduction ◇ Product Features◇ Technical Indicator

[Product Introduction]

The standard platinum resistance thermometer is an interpolation instrument that transmits the international temperature standard in the range of 13.8033K-960.78℃. It is used as a standard when verifying various standard thermometers and precision temperature measuring instruments. It can also be directly used for high-accuracy measurement in the above temperature zone. The standard platinum resistance thermometer measures temperature according to the law that the resistance of metallic platinum changes with temperature.According to the regulations of ITS-90, T90 is defined by platinum resistance thermometer in the temperature range from the equilibrium hydrogen triple point (13.8033K) to the silver freezing point (960.78℃). It uses a set of defined fixed point and reference functions as well as interpolated temperature deviation functions to index. The above-mentioned temperature zone is further divided into several temperature zones, and a sub-temperature zone that can work normally is determined by thermometers of different structures.

[Technical indicators]

ModelL(㎜)Use temperature zoneThe main technical parameters
WZPB—10 Working reference platinum resistance thermometer5000-419.527℃  -183~420℃R0=25±1Ω;R100/Rtp≥1.3926
WZPB—1 First class standard platinum resistance thermometer4800-419.527℃  -183~420℃R0=25±1Ω;R100/Rtp≥1.3925
WZPB—2 Second Class standard platinum resistance thermometer4800-419.527℃   -183-420℃R0=25±1Ω;R100/Rtp≥1.3925
WZPB—6 Working reference platinum resistance thermometer5300-660.323℃   -183-660℃R0=25±1Ω;R100/Rtp≥1.39254
WZPB—7 First class standard platinum resistance thermometer5300-660.323℃   -183-660℃R0=25±1Ω;R100/Rtp≥1.39254
WZPB—8 Second Class standard platinum resistance thermometer5300-660.323℃   -183-660℃R0=25±1Ω;R100/Rtp≥1.39254
Standard Platinum Resistance Thermometer 2020-12-9 This article was read 3266 Times
Previous:PartnerNext:Partner

Technical

Contact us

Taian Demei Electromechanical Equipment Co.,LTD.

Address:No. 8, Hedong Road, Shengzhuang Town, Taishan District, Taian, Shandong,China (Mainland)

Tel: +86-538-6518016 / 6518018

Mobile: +86-186 5382 5886

Whatsapp: +86-186 5382 5886   Skype: +86 186 5382 5886

Contact: Grace   Email: grace@demeithermo.com

Sales network

Taian Demei Electromechanical Equipment Co.,LTD.                          Publicity